- Has main feedback pot been rotated, or does it need rotating because the unit has been subjected to change in direction of movement on loss of signal? See section 4.11 – Resetting Feedback Pot.
- Is air supply clean, dry, and oil free?
Unit moves slower than expected up-scale or downscale:
- Check air pressure – above 50psi / 3.5 Bar?
- Check flow adjuster screws – has one been screwed in?
- Is air supply clean, dry and oil free? If not there is a possibility that the positioner servo has been damaged.
Movements are too jerky:
- Adjust proportional gain to increase smoothness – then reset damping and setpoints as instructed in Section 4.
Lack of sensitivity to changes in signal:
- Adjust proportional gain to increase sensitivity – then reset damping, and setpoints as instructed in Section 4.
Set point is overshot when positioner moves rapidly:
1. 目录.
页数. 章节
1 1. 目录
2 4.7比例增益和阻尼设置
3 4.8低电流和高电流点设置
4 4.9定位器的顺时针和逆时针转换
4 4.10失去信号时如何改变方向
5 4.11重新设置反馈电位计
6 4.12 EEPROM存储器校验和错误
6 4.13选择和设置非线性曲线
7 4.14设置可选角度跨距与调零
8 4.15调节可选圆锥型显示器的位置
9 5.文护和故障排除
.7比例增益和阻尼设置(稳定性和灵敏度)
选择安装模式,并且第一个参数选择是自动PGAIN—比例增益。按压SET键,PGAIN指示灯将开始闪亮,此时可通过按压UP或者DOWN键该参数值就增大或者减小。有29个可被选择的PGAIN设置,每按压UP或者DOWN键一次,其增益设置值改变为1.1倍。中间一个为默认设置,默认设置上面十四个和下面十四个都给予设置。超过第十四次按键就没有效果。